November 18, 2026
Journal Article
Standoff detection of carbon monoxide from the underground high explosive detonation in Physics Experiment 1-A using swept-wavelength ECQCL spectroscopy
Abstract
We report measurement results using a custom-built standoff infrared spectroscopy instrument for above-ground detection of CO generated in the Physics Experiment 1-A test, in which 13,580 kg of high-explosives were detonated in an enclosed underground chamber. The instrument used a swept-wavelength external cavity quantum cascade laser (swept-ECQCL) scanning over a wavenumber (wavelength) region of 1965-2290 cm-1 (4.37-5.09 µm) at a 100 Hz rate. The system was configured for standoff open-path measurements with a 223 m distance between the swept-ECQCL instrument and a retro-reflecting mirror, with the beam passing directly above a vent connected to the underground P-tunnel complex. Measured spectra were averaged to 1 Hz, and spectral fitting provided column densities of CO, CO2, H2O and N2O, and a spectroscopic temperature. Measurements were recorded over a continuous 27-day period after the PE1-A detonation, and CO was detected above ambient levels throughout this period. In contrast to the slow changes in the atmospheric background, the CO emitted from the vest consisted of fast variations in column density above ambient levels, with 90% of the detections having a durationPublished: November 18, 2026