March 27, 2025
Report

Evaluation of Commercial Advanced NDE

Abstract

Report: “Evaluation of Advanced Phased-Array Techniques: Interim Results”, August 2023 ML23216A009, PNNL-34622 Results showed that detection rate drops as microstructures/materials become more complex Standard PA had the highest detection rates overall Detection rates in the CASS-CASS mockups were lowest overall FMC had the most accurate length sizing in the fine-grained WSS mockups. All methods struggled with length sizing in coarse-grained mockups SNR vs method depended on the specimen type SNR was consistently high with standard PA SNR was consistently the lowest with PWI FMC performed best on fine-grained WSS A lack of data received from some Round Robin participants resulted in low statistics for many of the analyses

Published: March 27, 2025

Citation

Prowant M.S., R.E. Jacob, C.A. Hutchinson, J.M. Harrison, A.E. Holmes, and A.A. Diaz. 2024. Evaluation of Commercial Advanced NDE Richland, WA: Pacific Northwest National Laboratory.