The procedure designed for measuring angular distributions of gamma radiation and for search of gamma radiation intensive sources is described. It is based on application of the original multidetector device ShD-1, for measuring an angular distribution in a complete solid angle (4 pi). The calibration results and data on the angular distributions of intensity of gamma radiation at the roof of Chornobyl NPP "Shelter" are presented.
Revised: September 8, 2006 |
Published: August 8, 2005
Citation
Batiy V., A. Klyuchnykov, N. Kochnev, V. Rudko, v. shcherbin, V. Yegorov, and E.A. Schmieman. 2005.A Device for Search of Gamma-Radiation Intensive Sources at the Radiation Accident Condition. In ANS Topical Meeting on Decommissioning, Decontamination, & Reutilization, Aug 7-11 2005, Denver, CO, 228-232. La Grange Park, Illinois:American Nuclear Society. PNWD-SA-6950.