August 28, 2025
Journal Article

Detecting 127Xe in an Atmospheric Tracer Experiment

Abstract

The Xcounts algorithm for calculating air concentrations of radioactive xenon isotopes (Eslinger et al., 2023) has been extended to estimate 127Xe in addition to 131mXe, 133mXe, 133Xe, and 135Xe. The algorithm was applied to 119 samples collected with a SAUNA QB system (Ringbom et al., 2023) during a two-month atmospheric tracer release experiment. The algorithm identified two samples with 127Xe present from a single 1.5 h release about 3.5 km upwind of the sampler and no false detections of 127Xe were observed in the other samples.

Published: August 28, 2025

Citation

Eslinger P.W., M. Goodwin, R.S. Sarathi, G.A. Warren, B.T. Schrom, M.P. Foxe, and D. Chester, et al. 2025. Detecting 127Xe in an Atmospheric Tracer Experiment. Journal of Environmental Radioactivity 282:Art. No. 107614. PNNL-SA-204095. doi:10.1016/j.jenvrad.2025.107614

Research topics