The Spectral Deconvolution Analysis Tool (SDAT) software was developed to improve counting statistics and detection limits for nuclear explosion radionuclide measurements. SDAT utilizes spectral deconvolution spectroscopy techniques and can analyze both ß-? coincidence spectra for radioxenon isotopes and high-resolution HPGe spectra from aerosol monitors. The deconvolution algorithm of the SDAT requires a library of ß-? coincidence spectra of individual radioxenon isotopes to determine isotopic ratios in a sample. In order to get experimentally produced spectra of the individual isotopes we have irradiated enriched samples of 130Xe, 132Xe, and 134Xe gas with a neutron beam from the TRIGA reactor at The University of Texas. The samples produced were counted in an Automated Radioxenon Sampler/Analyzer (ARSA) style ß-? coincidence detector. The spectra produced show that this method of radioxenon production yields samples with very high purity of the individual isotopes for 131mXe and 135Xe and a sample with a substantial 133mXe to 133Xe ratio.
Revised: September 25, 2008 |
Published: September 23, 2008
Citation
Haas D.A., S.R. Biegalski, and K.M. Foltz Biegalski. 2008.Production of Samples of Individual Radioxenon Isotopes Through Neutron Irradiation of Stable Xenon Gas. In Ground-Based Nuclear Explosion Monitoring Technologies, 30th Monitoring Research Review, 749-757. Los Alamos, New Mexico:Los Alamos National Laboratory.PNNL-SA-61589.