Furnace System Testing to Support Lower-Temperature Stabilization of High Chloride Plutonium Oxide Items at the Hanford Plutonium Finishing Plant

Abstract

High chloride content plutonium (HCP) oxides are impure plutonium oxide scrap which contains NaCl, KCl, MgCl2 and/or CaCl2 salts at potentially high concentrations and must be stabilized at 950°C per the DOE Standard, DOE-STD-3013-2000. The chlorides pose challenges to stabilization because volatile chloride salts and decomposition products can corrode furnace heating elements and downstream ventilation components. Thermal stabilization of HCP items at 750°C (without water washing) is being investigated as an alternative method for meeting the intent of DOE STD 3013-2000. This report presents the results from a series of furnace tests conducted to develop material balance and system operability data for supporting the evaluation of lower-temperature thermal stabilization.