September 14, 2000
Report

Evaluation of SAFT/T-SAFT Technology for the Inspection of Hanford's Double Shell Waste Tank Knuckle Regions

Abstract

Results of the examinations conducted at Pacific Northwest National Laboratory provided a firm engineering basis for establishing the proof-of-principle effectiveness for utilizing a combination of pulse-echo Synthetic Aperture Focusing Technique (SAFT) and tandem-SAFT (T-SAFT) inspection methodologies as applied to the problem of flaw detection, localization, and sizing in Hanford's double shell waste tank knuckle region and beyond.

Revised: September 29, 2009 | Published: September 14, 2000

Citation

Pardini A.F., and A.A. Diaz. 2000. Evaluation of SAFT/T-SAFT Technology for the Inspection of Hanford's Double Shell Waste Tank Knuckle Regions Richland, WA: Pacific Northwest National Laboratory.