October 31, 2006
Report

Carbon Tetrachloride Flow and Transport in the Subsurface of the 216-Z-18 Crib and 216-Z-1A Tile Field at the Hanford Site: Multifluid Flow Simulations and Conceptual Model Update

Abstract

Carbon tetrachloride (CT) was discharged to the 216-Z-9, Z-1A, and Z-18 waste sites that are included in the 200-PW-1 Operable Unit in Hanford 200 West Area. Fluor Hanford, Inc. is conducting a Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) remedial investigation/feasibility study (RI/FS) for the 200-PW-1 Operable Unit. As part of this overall effort, Pacific Northwest National Laboratory (PNNL) was contracted to improve the conceptual model of how CT is distributed in the Hanford 200 West Area subsurface through use of numerical flow and transport modeling. This work supports the U.S. Department of Energy’s (DOE’s) efforts to characterize the nature and distribution of CT in the 200 West Area and subsequently select an appropriate final remedy.

Revised: November 29, 2006 | Published: October 31, 2006

Citation

Oostrom M., M.L. Rockhold, P.D. Thorne, G.V. Last, and M.J. Truex. 2006. Carbon Tetrachloride Flow and Transport in the Subsurface of the 216-Z-18 Crib and 216-Z-1A Tile Field at the Hanford Site: Multifluid Flow Simulations and Conceptual Model Update Richland, WA: Pacific Northwest National Laboratory.