Near- and mid-infrared diode lasers combined with flexible, hollow waveguides hold the promise of light weight, field portable, fast response gas sensors. The advantages of using the waveguides compared to White or Herriott multireflection cells include a small gas volume, a high photon fill factor in the waveguide, which increases molecule-light interactions, and reduction or elimination of optical fringing, which usually sets the practical limit of detectivity in absorption spectroscopy. Though hollow waveguides have been commercially available for several years, relatively few results have been reported in the literature. We present here results from our laboratory where we have injected infrared laser light into straight and coiled lengths of hollow waveguides and performed direct and wavelength modulated absorption spectroscopy on nitrous oxide, ethylene, and nitric oxide. Using a 1 mm bore, 3 meter long coiled waveguide coated for the near infrared, nitrous oxide transitions near 6595 cm-1 were observed under flowing conditions. Signal-to-noise ratios on the order of 1500:1 with RMS noise equal to 2 X 10-5 were measured. In the mid-infrared light from either a 10.1 or 5.3 micron lead salt diode laser was injected into a three meter length of 1 mm bore hollow waveguide coated for the mid-infrared. The waveguide was coiled with one loop at a diameter of 52 cm. Ethylene transitions were observed in the vicinity of 985 cm-1 with a static fill of 0.2 Torr of pure ethylene in the waveguide and nitric oxide transitions were observed in the vicinity of 1906 cm-1 using either a flow or a static fill of 1 ppm NO in nitrogen. In direct absorption the NO transitions are observed to have a signal-to-noise of approximately 5:1 for transitions with absorbances on the order of 10-3. Using wavelength modulated techniques the signal-to-noise ratio improves at least an order of magnitude. These encouraging results indicate that waveguides can be used for in situ gas monitoring.
Revised: December 23, 2002 |
Published: November 1, 2002
Citation
Blake T.A., J.F. Kelly, T.L. Stewart, J.S. Hartman, S.W. Sharpe, and R.L. Sams. 2002.Absorption Spectroscopy in Hollow-Glass Waveguides Using Infrared Diode Lasers [4817-25]. In Diode Lasers and Applications in Atmospheric Sensing : Proceedings of SPIE--the International Society for Optical Engineering : 10-11 July 2002, Seattle, USA, edited by Alan Fried, 4817, 216-232. Bellingham, Washington:SPIE - the International Society for Optical Engineering.PNNL-SA-36612.