January 30, 2017
Journal Article

A Simple Thick Target for Production of 89Zr using an 11 MeV Cyclotron

Abstract

The growing interest but limited availability of 89Zr for PET led us to test targets for the 89(p,n) reaction. The goal was an easily constructed target for an 11 MeV Siements cyclotron. Yttrium foils were tested at different thicknesses, angles and currents. A 90 degree foil tolerated 41 microAmp without damage and produced ~800 MBq/hr, >20 mCi, an amount adequate for radiochemistry research and human doses in a widely available accelerator. This method should translate to higher energy cyclotrons.

Revised: February 21, 2017 | Published: January 30, 2017

Citation

Link J.M., K.A. Krohn, and M.J. O'Hara. 2017. A Simple Thick Target for Production of 89Zr using an 11 MeV Cyclotron. Applied Radiation and Isotopes 122. PNNL-SA-117438. doi:10.1016/j.apradiso.2017.01.037