August 7, 2011
Conference Paper

Prototype Radiation Detector Positioning System For The Automated Nondestructive Assay Of Uf6 Cylinders

Abstract

International Atomic Energy Agency (IAEA) inspectors currently perform periodic inspections at uranium enrichment plants to verify UF6 cylinder enrichment declarations. Measurements are typically performed with handheld high-resolution sensors on a sampling of cylinders taken to be representative of the facility’s entire cylinder inventory. These measurements are time-consuming, expensive, and assay only a small fraction of the total cylinder volume. An automated nondestructive assay system capable of providing enrichment measurements over the full volume of the cylinder could improve upon current verification practices in terms of efficiency and assay accuracy. This paper describes an approach denoted the Integrated Cylinder Verification Station (ICVS) that supports 100% cylinder verification, provides volume-averaged cylinder enrichment assay, and reduces inspector manpower needs. To allow field measurements to be collected to validate data collection algorithms, a prototype radiation detector positioning system was constructed. The system was designed to accurately position an array of radiation detectors along the length of a cylinder to measure UF6 enrichment. A number of alternative radiation shields for the detectors were included with the system. A collimated gamma-ray spectrometer module that allows translation of the detectors in the surrounding shielding to adjust the field of view, and a collimating plug in the end to further reduce the low-energy field of view, were also developed. Proof-of-principle measurements of neutron and high-energy gamma-ray signatures, using moderated neutron detectors and large-volume spectrometers in a fixed-geometry, portal-like configuration, supported an early assessment of the viability of the concept. The system has been used successfully on two testing campaigns at an AREVA fuel fabrication plant to scan over 30 product cylinders. This paper will describe the overall design of the detector positioning system and provide an overview of the Integrated Cylinder Verification Station (ICVS) approach.

Revised: September 5, 2013 | Published: August 7, 2011

Citation

Hatchell B.K., P.L. Valdez, C.R. Orton, and E.K. Mace. 2011. Prototype Radiation Detector Positioning System For The Automated Nondestructive Assay Of Uf6 Cylinders. In 3rd International Joint Topical Meeting on Emergency Preparedness & Response and Robotics & Remote Systems (EPRRSD 2011), August 7-10, 2011, Knoxville, Tennessee, 1, 1-8. Lagrange Park, Illinois:American Nuclear Society. PNNL-SA-79849.