July 16, 2017
Journal Article

Muon Flux Measurements at the Davis campus of the Sanford Underground Research Facility with the Majorana Demonstrator veto system

Abstract

We report the first measurement of the muon flux underground at the Davis Campus of the Sanford Underground Research Facility at the 4850 foot level. Measurements were done with the Majorana Demonstrator veto system arranged in two different configurations. Both results are in agreement within statistical accuracy. The measured flux is (4.08+-0.19) x 10 -9 muons/cm/2. We compare our results with previous calculations.

Revised: June 15, 2020 | Published: July 16, 2017

Citation

Abgrall N., E. Aguayo, F.T. Avignone, A. Barabash, F. Bertrand, A.W. Bradley, and V. Brudanin, et al. 2017. Muon Flux Measurements at the Davis campus of the Sanford Underground Research Facility with the Majorana Demonstrator veto system. Astroparticle Physics 93. PNNL-SA-107386. doi:10.1016/j.astropartphys.2017.01.013